5g
PlasmaBlock® Air Cooled

5g<br/>PlasmaBlock® Air Cooled

Product Summary

The smallest PlasmaBlock® unit.  Available with a regular (PCB on the side) or alternate (PCB on top) mount. Regular mount has connection ports (oxygen in, ozone out) on top, alternate mount has ports on the side.  The 3/7g chassis is a miniature version of the 10g unit.  

Product Details

For added application information, see the PlasmaBlock Application Guide

Models available
Refer to - Configuration Options Summary Sheet 

Fully automatic tuning for constant ozone output and installation simplicity 
Service simplicity due to automatic fault diagnostics
Silent, Rugged, Reliable and Cost Effective
No exposed high-voltage safety hazards
3g @ 0.5% Air and 7g @ 5% Oxygen models in same chassis
Now available with PlasmaVIEW ® software (optional)

Design Features

  • 7g, 5%, 2 lpm, 6 psi.  
  • Directly installable by  UL 508a panel house,
  • Full-Auto and Semi-Auto modes hold constant power over the entire pressure range:   2 - 100 psi.  From package to process with no setup or adjustments required.  Continuously tracks and automatically optimizes performance for changes in pressure, flow and line voltage. 
  • Universal, world class product.  Constant ozone output and cooling: 1Φ 120 – 240vac, 50/60hz.   Power supply is UL / CSA / CE listed.  NO line voltage configuration jumpers – any voltage, any frequency;  same unit.
  • Efficient, compact, silent (25khz), safe, rugged, reliable, advanced – all the normal traits of a PTI product.  Same precise linear control, with turn down to 1%, as all Plasma Block products.
  • Maximum up-time , durable, commercial / industrial solution the ozone industry requires.
  • Possible cell flooding is identified followed by shut down and enunciation.  No damage is caused to electronics, transformer and rarely the cell.  Cell flushing and drying in the field is usually sufficient to restore full service.
  • Extensive two tier fault enunciation maximizes up-time and simplifies service diagnostics.  Latched fault indicators retain fault status until serviced.
  • This Gen1 Enhanced cell is a scaled down version of PTI’s field proven 10g product which is virtually impervious to extremes in temperature, vibration and pressure.  Major savings are had due to its low energy use, low oxygen volume needs and competitive price.
  • The control electronics is accomplished via Plasma Technics® new 310 microcontroller based inverter board.  This state of the art controller yields a simpler user interface and many new features intended to further increase up time and simplify installation and troubleshooting.
  • Control connections of the essential I/O functions are the same as all other Plasma Block products.
  • PDM, Voltage and Frequency potentiometers have their own jumper selection for on board control if desired.
  • Complex and thorough on board electronic short circuit protection prevent  nuisance circuit board failure due to accidental field wiring errors.
  • Power and control connection are located at the rear of the product to enable integrators to construct ‘plug & play’ mounting.
  • The 3/7g chassis is a miniature version of the 10g unit.  This means that the general location for control connections, gas IN/OUT, cooling, etc. are the same.
  • Military grade conformal coating eliminates problems associated with condensation and mold as well as greatly retarding damaged caused by accidental ozone exposure.
  • Unlike all other Plasma Block products, the feed gas supply must be very dry.
  • There is an inherent pressure drop associated with each Plasma Block.  This can vary depending on the desired flow.  Verification of the outlet pressure, at the desired flow, of the Plasma Block is crucial in order to prevent a negative pressure drop in the Plasma Block.  This will damage the Plasma Block internals and is not a warrantied repair.


Configuration options :
PTI will set up and tune units to the customers desired specifications.

Oxygen pressure - (2 - 100 psi)
Oxygen flow liters/minute - (1-2 Lpm) or equivalent SCFH
Heat load btu/hr = 297
Chassis (standard or alternate)
Inlet fittings (none, 1/4", other)
Outlet fittings (none, 1/4", other)
Weight Lbs (Kg) : 7.6 (3.45)

Related Manuals

(pdf format, view or download) 

Installation Operation 
Quick Start 
Dimension Drawing 
How to read the performance graphs 
PlasmaBlock Performance Specs (heat dissipation, current, ozone output)
Spec Sheet 

Product Photos

Output Performance Charts

Training and Instructional Videos

DAT210 Set Power Point

DAT210 Start Button Sweep

DAT210 New Profile Procedure

DAT210 Normal Running

DAT210 LED Fault Indicators

DAT210 Connection Safety Considerations

DAT210 On Delay Timer

Fuse and Power Supply Testing

16 Pin Kit Testing

DAT210 Firmware 3 1

SSD110 Tuning

IGBT and Diode Bridge Testing

Installation Drawings

overview
overview
front
front
back
back
top
top
bottom
bottom
overview alt mount
overview alt mount
front alt mount
front alt mount
back alt mount
back alt mount
side alt mount
side alt mount
top alt mount
top alt mount
top2 alt mount
top2 alt mount
bottom alt mount
bottom alt mount