<--Back       Product Pictures      Product Specs (pdf)

      1kva to 16kva  /  low - med freq

                                                    Severe Application - Ozone Transformers  

Case size 100, 200, 300, 400
UL & CSA Recognized Component.

Design Features:

Installation Drawing  

            oil1kva4kva_004                    

    Dimensional Table    Inches (mm)

 

Case100

 

Case110

 

Case200

 

Case300

 

Case400

A

4      (102)

5   (127)

5    (127)

6      (152)

8      (203)

B

6.13  (156)

7.63  (194)

7.5  (191)

9.13  (232)

11.25 (286)

C

8.63 (219)

10.80 (274)

9.5  (241)

10.63 (270)

15.13 (384)

D

5.88 (149)

7.35  (187)

7.25 (184)

8.88  (225)

10.88 (276)

E

7     (178)

9.30  (236)

8     (203)

9       (229)

12.63 (321)

F

7.13 (181)

5.95  (151)

9     (229)

10.63 (270)

13     (330)

G

1      (25)

.88    (22)

1      (25)

1.25   (32)

1.5     (38)

H

6      (152)

4.07  (103)

7.5  (191)

9       (229)

11.38 (289)

I

4.63 (118)

4.07  (103)

6     (152)

8.13  (206)

10.38 (264)

Mt

8     (203)

10     (254)

9     (229)

10     (254)

14.38 (365)

Mt=bolt mounting center; mounting slot designed for ¼-20 bolt for all except the Case400, which is 3/8”; H.V. terminal is 1 ¼” to 1 ½” from left side, as shown above. All terminals use 10-32 nuts.  High-voltage terminal extends the ‘E’ dimension by:  <12kv 1 ¾”,  <20kv 2 ¼”,  <30kv 3 ¾”

 

Performance Information



Item


Catalog #

Primary
Volts / Hz

Max
KVA

Output

KvRMS

Sec
MA


Style

Case
Size

Weight
Lbs(Kg)

1

300-LLHI06402/D220

220/440:50-60

4

6

500

End Gnd

300

113  (51)

2

110-LLHI08122/D115

115/230:50-60

1.2

8

150

End Gnd

110

49  (22)

3

200-LLHI08242/D220

220/440:50-60

2.4

8

300

End Gnd

200

74  (34)

4

110-LLHI10122/D115

115/230:50-60

1.2

10

120

End Gnd

110

49  (22)

5

100-LLH10122/T220

220/240/260:50-60

1.2

10

120

End Gnd

100

44  (20)

6

200-LLH10242/D220

220/440:50-60

2.4

10

240

End Gnd

200

74  (34)

7

300-LLH10402/D220

220/440:50-60

4

10

400

End Gnd

300

113  (51)

8

110-LLHI15122/D120

120/240:50-60

1.2

15

85

End Gnd

110

46  (21)

9

200-LLH25062/D120

120/240:50-60

.6

25

24

End Gnd

200

70  (32)

10

**55-MLH04501/T100

*160 : 1.2khz

1

4

250

End Gnd

55

17    (8)

11

**55-HLH06102/D115

* 115/230:1.2khz

1

6

167

End Gnd

55

17    (8)

12

100-HLH06302/D230

* 230/460:1.2khz

3

6

500

End Gnd

100

40  (18)

13

300-HSHI06802/D230

* 230/460:1.2khz

8

6

1400

End Gnd

300

136  (62)

14

400-HSHI06123/D230

* 230/460:1.2khz

12

6

2100

End Gnd

400

225(102)

15

100-HLH08302/D230

* 230/460:1.2khz

3

8

375

End Gnd

100

40  (18)

16

** 55-HLH10102/D115

* 115/230:1.2khz

1

10

100

End Gnd

55

17    (8)

17

100-HLH10302/D230

* 230/460:1.2khz

3

10

300

End Gnd

100

40  (18)

18

300-HLHI10602/D230

* 230/460:1.2khz

6

10

600

End Gnd

300

136  (62)

 

 

 

 

 

 

 

 

 

Þ   oil1kva4kva_005   UL & CSA Recognized Component.

 

Product with letter ‘I’ in the sales code is isolated secondary ground type.
*  Hz is nominal, ± 50% frequency with 100% VA rating ; max case temp 65°C.
**  See ‘70 – 150va  / low frequency data sheet for dimensional table.