<--Back       Product Pictures      Product Specs (pdf)

                                                              OEM

 50g @ 5%     23g @ 8%   Plasma   Blo3ck ®   (Air-cooled) 

 

For added application information, see the Plasma Block® Application Guide manual.

 

Models available :
Refer to - Configuration Options Summary Sheet

Silent, Rugged, Reliable, Cost-effective, Compact and Light Weight, Ceramic,  Air-cooled and power-Efficient.
24g / hr (1.3 ppd)@ 8% weight and 3 lpm. 40g / hr (2.1 ppd) @ 5% weight and 10 lpm (oxygen or
concentrator at 300 watts.

No exposed, high-voltage safety hazards.
Precise ozone control using Pulse Density Modulation  (PDM) via potentiometer, 4/20ma or 0-10vdc.
Precise Control with Turn-down to 1%.
Useful pressure range:  5 – 100 psi.
Now available with PlasmaVIEW ® software (optional).

Design Features:

Configuration options :
PTI will set up and tune units to the customers desired specifications.

Oxygen pressure - (5 - 100 psi) (UL 5x rated)
Oxygen flow liters/minute - (3 - 15 Lpm) or equivalent SCFH
Heat load btu/hr = 1360
Chassis (regular or alternate)
Inlet fittings (none, 1/4", 3/8", other)
Outlet fittings (none, 1/4", 3/8", other)

Weight Lbs (kg) : 13.5 (6.22)

Installation Drawing Standard Mount : inches   

 

 

 

 

Installation Drawing Alternate Mount : inches   

 

Output Performance: 

Normal factory Power set point: 440 watts at FULL PDM (10vdc or 20ma).

Published production-ozone output level (45 gr/hr) based on 5% concentration.

Test conducted at 23C (74F), 700' (213M) MSL: Ozone in g/nm3.

Flow measured in LPM via uncorrected rotameter at inlet port.

Fan and power supply burden of 40 watts is included in above chart.

 

Procedure 1, Grams per hour desired at maximum power:

1. Determine the grams/hr desired for the chemical reaction. 45 gram/hr for this example.

2. Moving vertically from the value on the horizontal scale at 45 gr/hr, note the % weight (Blue line)
on the left axis at 5 % wt for the maximum power at 45 gr/hr.

3. At the same Grams/hr value move vertically and note both the SLPM at 10.5 SLPM (red) and
indicated LPM (green) at 8.5 LPM at the recommended pressure [0.68 bar (10 psi)]on the right vertical axis.

4. If a higher % weight is desired at the grams/hr needed, a larger generator must be selected. A generator
can always be run at a lower power than maximum with the PDM control.

 

Procedure 2 example, Oxygen flow of 6 LPM maximum at 0.68 bar (10 psi) on a rotameter.

What is the maximum gr/hr production ?

1. Start on the right vertical scale at 4 LPM rotameter reading.  Move horizontally to intercept the
green LPM line at 6 LPM.

2. Drop down vertically to see what gr/hr is available.  It is 37 gr/hr in his case.

3. Move vertically to intercept the red SLPM line at 7 SLPM and the blue % wt line at 6.2% wt.