DAT210 70250 Inverter Assembly

 

(3 phase assembly shown) Version V1a

Table of Contents

 

Section 1        Reasons for specifying the assembly                                                                       3

Section 2        Circuit description                                                                                                     4

Section 3        Bill of Materials                                                                                                         4

 

Section 4        Dimensions                                                                                                                 5

 

Section 5        Disclaimer                                                                                                                   6

 

Please refer to the DAT 210 or SSD 110 manuals for inverter specific installation and operational details.

 

SECTION 1.                                         REASONS FOR SPECIFYING THE ASSEMBLY

The DAT210 inverter component is designed with a single phase line rectifier providing pulsating direct current (DC) to large input filter capacitors. If the line is connected directly to the line input of the inverter, there will be an initial large inrush current to charge the capacitors. This current is only limited by the mains source (wiring and utility transformers) and filter capacitor internal resistance. The effect is particularly pronounced when the inverter is operated from 240 VAC single or 3 phase at power over 1 KVA.

 

There are three disadvantages to directly connecting the line to the inverter.

 

1. High inrush can stress the filter capacitors shortening its life.

2. High inrush currents can stress the safety circuit breakers (and will blow fuses) that may work fine during testing but will deteriorate over time causing nuisance trips.

3. Connecting any rectifier filter capacitor directly to the line causes a strong 3rd harmonic line current causing a 0.6 power factor. Many companies prefer clean (low harmonics) devices in their facility to lessen interference with other more sensitive equipment.

 

The 70250 inverter assembly solves these problems. A soft-start relay circuit is automatically controlled by the inverter, pre-charge components limit inrush currents and a high current link choke to eliminate the harmonics and correct the power factor to 0.95.

 

Lastly, the assembly is cost effective by eliminating the need to individually design and mount these essential components.

 

 

SECTION 2.     Suggested soft start circuits

Circuits are shown for both single phase (top) and three phase inputs (bottom). Components to the right of the inverter are typical ozone generator components.

 

A general rule is to use the three phase circuit if the generator is rated over 2 KW. However this is a matter of individual preference.

 

Section 3        Bill of Materials

INVERTER 70250 ASSEMBLY

 

 

QUANTITY

PART NO.

DESCRIPTION

SOURCE

NOTES

 

1

U2125A330L

Ceramic surge resistor

HVRA

716.693.4700  www.hvrapc.com

 

1

W9AS1D52-5

30 Amp 5 VDC coil relay

Magnecraft

866.433.5722 www.alliedelec.com

 

1

DF30AA160

30 Amp three phase rectifier

SanRex

516.625.1313

 

1

0.2 uF  1600 VDC/530 VAC capacitor

ASC or PTI

308.284.3611   www.ascapacitor.com

 

1

235

14 Amp DC link choke (inductor)

PTI

4 KVA maximum

 

1

237

20 Amp DC link choke (inductor)

PTI

> 4 KVA use the 237

 

1

DAT210

Inverter to 4 KW

PTI

Purchased separately

 

Section 4        Dimensions

 

 

Section 5

DISCLAIMER

 

Plasma Technics, Inc. (PTI) assumes no responsibility or liability for specific applications results. PTI supplies only components for ozone systems and not the complete system. The complete system is the responsibility of the ozone system manufacturer and/or others involved in a specific project.