<--Back Product Pictures Product Specs (pdf)
OEM

For added application information, see the Plasma Block® Application Guide manual.
Models available :
Refer to - Configuration Options Summary Sheet
Silent, Rugged, Reliable, Cost-effective, Compact and Light Weight, Ceramic, Air-cooled and power-Efficient.
1.1 lbs/day at 6.7% and 3 LPM : 1.9 lbs/day at 3.5% weight and 10 LPM (Oxygen or Concentrator)
No exposed, high-voltage safety hazards.
Precise ozone control using Pulse Density Modulation (PDM) via potentiometer, 4/20ma or 0-10vdc.
Precise Control with Turn-down to 1%.
Now Available with PlasmaVIEW ® software (optional)
Design Features:
Configurations options :
PTI will set up and tune units to the customers desired specifications.
Oxygen pressure - (5 - 86 psi) (UL 5x rated)
Oxygen flow liters/minute - ( .1 - 20 Lpm) or equivalent SCFH
Heat load btu/hr = 860
Inlet fittings (none, 1/4", 3/8", 8mm, 10mm other)
Outlet fittings (none, 1/4", 3/8", 8mm, 10mm, other)
Weight Lbs (Kg) : 16.5 (7.49)
Installation Drawing: Inches


Output Performance:

Output Performance: 5 psi
% Weight vs Power Consumption


Grams / Hour vs Power Consumption
Normal factory POWER set point: 250 watts at FULL PDM ( 10vdc or 20ma ).
Published production-ozone output level (30gr/hr) based on 5% concentration.
Tests conducted at 72°F, 700’ MSL, all pressure readings in psig. Ozone in g/nm3.
Flow measured in LPM via uncorrected Rotameter at inlet port.Ozone at 0 psi from side-stream.
Output Performance: 10 psi
% Weight vs Power Consumption


Grams / Hour vs Power Consumption
Normal factory POWER set point: 250 watts at FULL PDM ( 10vdc or 20ma ).
Published production-ozone output level (30gr/hr) based on 5% concentration.
Tests conducted at 72°F, 700’ MSL, all pressure readings in psig. Ozone in g/nm3.
Flow measured in LPM via uncorrected Rotameter at inlet port.Ozone at 0 psi from side-stream.
Output Performance: 15 psi
% Weight vs Power Consumption


Grams / Hour vs Power Consumption
Normal factory POWER set point: 250 watts at FULL PDM ( 10vdc or 20ma ).
Published production-ozone output level (30gr/hr) based on 5% concentration.
Tests conducted at 72°F, 700’ MSL, all pressure readings in psig. Ozone in g/nm3.
Flow measured in LPM via uncorrected Rotameter at inlet port.Ozone at 0 psi from side-stream.
Output Performance: 20 psi
% Weight vs Power Consumption


Grams / Hour vs Power Consumption
Normal factory POWER set point: 250 watts at FULL PDM ( 10vdc or 20ma ).
Published production-ozone output level (30gr/hr) based on 5% concentration.
Tests conducted at 72°F, 700’ MSL, all pressure readings in psig. Ozone in g/nm3.
Flow measured in LPM via uncorrected Rotameter at inlet port.Ozone at 0 psi from side-stream.
Flow vs % Weight (250 Watts)

PDM Control Voltage vs Input Power ( Watts)