35-150  watt  /  low frequency

 

                         Severe-Application Ozone Transformers

 

·         Designed specifically for harsh electrical and environmental demands imposed by continuous-duty, corona-discharge, ozone-generation, and electrostatic applications.  UL and CSA  Recognized Component.

·         Completely sealed for Maximum Life, and Resistance to harsh environments, the design features assure a significant increase in operational performance where standard ignition and neon transformers routinely fail.

·         Cost-effective, compact and high generation-efficient design, typically capable of supporting twice the ozone generation load of a conventional transformer.

·         Vacuum impregnation-sealed for long service life in severe service applications such as corona-discharge, ozone-generation, electrostatics, and static bars.  2-year limited warranty for all applications including corona-discharge ozone generation.

 

 

 

 

 

 

 

Design Features:

·         Complex impregnation and premium materials surround the critical components, ensuring a virtual corona-free operating environment within the enclosure, and a long service life that rivals oil.

·         This short-circuit-proof, current-limiting transformer is designed to withstand continuous operation in the most demanding of electrical and temperature environs.

·         All copper windings, a rugged high-temperature and high-voltage insulation system, housed in a very compact, vacuum- sealed enclosure, ensure operation at 65°C.

·         Separate ground wire ensures proper grounding to the generator and enclosure.

·         Standard KV configurations are end point ground 4, 5, 6.5, 7.1, 8.5, 10, 11.4 units in power ranges from 35 to 150 watts.  Standard designs are 120v/60hz & 220v/50:60hz.  Consult the factory for custom configurations.

·         All mounting brackets are Stainless Steel.

·         Premium high-voltage wire for  Maximum Life.

·         Custom terminations and wire lengths upon request.

·         Highly qualified technical support with a thorough understanding of ozone applications.


Installation Drawing Dimensional Table    Inches

 

 

 

 

Cup 12 series:

 

 

 

 

 

Cup 15 series:

 

 

Performance Information


 

 

Item



Cat #


Primary
Volts/Hz

Max
Pri
VA

Typical
Loaded
Watts

Open
Sec
KvRMS

Short
Sec
MA



Style


Case
Size


Weight

Lbs(Kg)

1

12-103.510

120/60

55

40

3.5

10

End Gnd

12

4.2 (1.9)

  2

12-10416

120/60

60

40

4

16

End Gnd

12

4.2 (1.9)

3

12-20416

230/50-60

60

40

4

16

End Gnd

12

4.2 (1.9)

 4

12-10510

120/60

80

40

5

10

End Gnd

12

4.2 (1.9)

     5

12-106.510

120/60

115

40

6.5

10

End Gnd

12

4.2 (1.9)

6

12-206.510

230/50-60

130

35

6.5

10

End Gnd

12

4.2 (1.9)

7

15-304.256

115/230 /50-60

280

150

4.2

56

End Gnd

15

9.0 (4.0)

8

15-107.130

120 /50-60

230

150

7.1

30

End Gnd

15

9.0 (4.0)

9

15-108.527

120 / 50-60

225

150

8.5

27

End Gnd

15

9.0 (4.0)

10

15-310.030

120/230:50-60

310

150

10

30

End Gnd

15

9.0 (4.0)

11

15-111.420

120 /50-60

293

150

11.4

20

End Gnd

15

9.0 (4.0)

 

 

 

 

 

 

 

 

 

 

Þ           All Above; Specials and wire configuration available upon request.